The Ambry Way homeowner in Indianapolis proceeded with a Liberty Mutual roofing claim. Indy Roof & Restoration finalized a shingled-roof project.
The shingle installation was recorded complete December 14, 2023, using Owens Corning Oakridge AR and ProEdge in Onyx Black. Its order included 135 linear feet of hip and ridge, 17 squares of second-story labor, 97 linear feet of step flashing, 61 linear feet of wall flashing and flashing at three chimneys. The low-slope rear section called for ice-and-water protection across the entire slope, alongside RhinoRoof UDL and Starter Strip Plus in the broader assembly.
The roof included VentSure ridge ventilation, black drip edge and gutter apron, and pipe flashing. Detach-and-reset of the lightning rods and grounding wire was included in the crew's scope, with a separate caution to preserve the animal-exclusion wiring at the front-left elevation. During construction, one OSB sheet of localized decking was replaced.
At the rear roof-to-wall junction, existing white window flashing complicated the connection to new black wall flashing. The team discussed changing the roof flashing to white or retaining black while wrapping the existing white window flashing around the corner to meet it. The homeowner selected the latter arrangement, allowing the window wraps to remain while the new wall-flashing work proceeded.
Carrier review increased the scope, including edge metal, ice-and-water protection, starter, lightning-system and cornice-return allowances. Completion approval followed December 20, and the homeowner rated the experience five out of five in the subsequent satisfaction check. The finished contract covered the shingle roof and its associated details.
Project details
- Location
- Ambry Way, Indianapolis, Indiana
- Property type
- Residential home
- Project context
- Insurance-related roofing work
- Scope
- Shingled roof replacement and localized OSB decking
- Shingles
- Owens Corning Oakridge AR in Onyx Black
- Hip and ridge
- Owens Corning ProEdge in Onyx Black
- Roof components
- Tarco LeakBarrier MS300, RhinoRoof UDL and Owens Corning Starter Strip Plus
- Ventilation
- Owens Corning VentSure ridge vent
- Roof edge metal
- Black drip edge and gutter apron
- Flashing
- Pipe, step, wall and chimney flashing
- Rear roof-to-wall junction
- New black wall flashing joined existing white window flashing
- Work period
- December 2023
- Roof Completion Record
- December 14, 2023
- Hip and Ridge
- 135 linear feet
- Flashing
- 97 linear feet of step flashing; 61 linear feet of wall flashing; three chimneys
- Decking
- One OSB sheet replaced
- Low-Slope Detail
- Full ice-and-water protection specified on rear slope
- Carrier Scope
- Revised
- Completion Approval
- December 20, 2023