A hail claim on this Indianapolis home led to a new roof, new gutters and repairs to the soffit and fascia in a few spots. The homeowner chose to keep two newer rear roof slopes, because no damage had been found on them. Indy Roof & Restoration tied the new roof into those slopes.
We installed Owens Corning TruDefinition Duration AR shingles in Driftwood. Matching ProEdge hip and ridge shingles cover 236 feet of hips and ridges. Under the shingles went Starter Strip Plus, Tarco LeakBarrier MS300 ice and water protection and ABC Pro Guard 20 synthetic underlayment. The roof also has seven black Lomanco slant-back vents, black edge metal and pipe flashing. Our crew built a chimney cricket and installed a large new chimney flashing.
Fascia and soffit were damaged at corners of the house. We put in 56 feet of treated Woodtone RealTrim fascia and 28 feet of soffit, then painted the trim and soffit with color-matched paint. Our gutter crew hung 261 feet of Royal Brown six-inch gutters with three-by-four-inch downspouts. Dark Bronze gutter guards cover 248 feet of those gutters.
The insurance company approved more work after the roof went on. That added the ice and water protection, drip edge, chimney cricket and chimney flashing, and the claim went up. After the insurance company reviewed our completion papers, it paid the remaining part of the claim. The homeowner also financed part of the project cost. The roof was finished August 8, 2025, and the fascia, soffit and gutters were finished August 12, 2025.
Project details
- Location
- Indianapolis, Indiana
- Project Type
- Roof replacement on selected slopes with gutters and soffit/fascia work
- Property Type
- Residential
- Funding
- Insurance with financing for part of customer payment
- Insurance/Appraisal
- Post-production supplementation and completion-document review
- Roofing System
- Architectural asphalt shingles tied into retained rear slopes
- Manufacturer
- Owens Corning
- Product
- TruDefinition Duration AR
- Color
- Driftwood
- Additional Work
- Chimney cricket and flashing, full gutters, gutter guards, fascia and soffit work and painting
- Roof Scope
- Replacement tied into two retained newer rear slopes
- Roof Intersections
- 236 linear feet of hip and ridge; chimney cricket and flashing
- Fascia and Soffit
- 56 linear feet of treated fascia; 28 linear feet of soffit; painting
- Gutters and Guards
- 261 linear feet of Royal Brown six-inch gutters; 248 linear feet of Dark Bronze guards
- Supplemental Scope
- Increased allowances
- Construction
- Roof August 8, 2025; fascia, soffit and gutter orders August 12, 2025